Excellent solvent cement for bonding irrigation, electrical conduit and plumbing PVC pipe joints
Step 1 : Cut the pipe
Step 2 : Remove burr, roughen and clean the outer surface of the pipe and inner surface of the socket
Step 3 : Check the dry fit of pipe & fitting. It should go up to end of the fitting easily. Use Solvobond primer if require
Step 4 : Apply first coat of Solvobond uPVC 606 evenly using suitable applicator on outer surface of the pipe and inner surface of the socket. Apply second coat on pipe till socket depth
Step 5 : Twist the pipe 45°-90° while inserting into the socket for better spreading of Solvobond uPVC 606 and hold for 30 sec.
Step 6 : Wipe off excess cement and leave the surface untouched for one hour for perfect bonding
Step 7 : Partially emptied container should be close immediately..
Step 8 : Allow 5 min to get good handling strength. 30 min for strength upto 160 psi interference fit upto 2” For pipe size 2” or larger, temperature below 15°C & higher pressure longer cure time is require.
High solid content
Low VOC
Meets ASTM D 2564 Standards
Shelf Life: 18 months from the date of manufacturing.
Storage: Product should be stored in a dry place in their original, properly closed containers.