Back

Trubuild

Overview Usage Product Specifications Handling Precautions
TRUBUILD WALLTECT TOPCOAT

TRUBUILD WALLTECT TOPCOAT is high grade Acrylic base single component elastomeric durable waterproof exterior coating, which is made with selected and graded fine fillers, with biocides additive for exterior wall. It has excellent flexibility, breathability, water resistance, crackbridging, weathering durability and an excellent resistance to the growth of microorganisms.

 

Application
Applications
  • Facades
  • External walls
  • Masonry walls
  • Exterior RCC
  • Cement sand rendering
Application
Advantages
  • Excellent waterproofing system.
  • Durable coating.
  • Excellent resilience to thermal stress.
  • Eco friendly.
  • Excellent weather resistance.
  • Maintain good aesthetic look.
  • Provides excellent barrier to carbonation and Chlorination
How to use
How to use

Surface Preparation

For old structure remove the loose unsound materials, oil, dirt, debris, existing paint, waterproof coatings or any type of other surface contaminations from the substrates. Treat any areas affected by Algae, moss or fungal growth with biocide wash solution. This is accomplished by pressure cleaning equipment with a minimum capability of 100-140 bar water pressure. For new construction remove all loose unsound materials, grease, oils etc must be removed completely by help of sand papers or pressurised water blasting. Fill all the existing cracks up to 5 mm by making “V” groove and then filling it with Trubuild crack filler paste (CFP 425). For cracks larger than 5mm use Polymer modified mortar making with Trubuild WPL 333/Trubuild BWP 222.

 

Application

  • Before application of Trubuild Walltect Top coat, a primer coat with Trubuild primesure Primer on the substrate should be done. During application of primer, it is to be ensured that the surface should be in Saturated Dry Condition(SSD). For Filling the pores on the surface and providing good bonding to subsequent upcoming waterproofing layer use Trubuild Primesure primer in 2:1 (50% dilution with water) chemical to water ratio by weight, mix it well till we get homogeneous mixture using Low RPM paddle mixture. Before applying primer use air blower (Don’t use Hot air blower) to remove the dust present on surface, if any. The coverage of primer coat will be approx. 8-10sqmtr per ltr per coat, depending upon the substrate condition and apply all over the wall. After drying of Primer coat around 6-8 hours apply apply 1st coat of Trubuild walltect Top coat horizontally without any dilution. Allow the first coat to dry for min. 6-8 hours. then apply 2nd coat vertically without dilution The application coverage should be maintained 35-40 sq.ft. per ltr per two coats. Then allow coating to air cure for min. 7- 10 days for fully curing.

 

TECHNICAL DETAILS

 

PROPERTIES STANDARD RESULTS
Appearance IN HOUSE Opaque, white
Solid (%) ASTM D 1644:01 55±2
Elongation@120 µ (%) ASTM D 412-2016 ≥ 160
Crack bridging ability (mm) EN 1062-7 >1
DFT (micron)   120 
Tensile strength (N/mm²) ASTM D 412-2016 ≥2
Density (gm/cc)   1.29±0.01
Pull of Adhesion, (Mpa) ASTM D 4541:2017 ≥2
Water Absorption (%), 24 hrs. ASTM D 471 < 10
Carbon dioxide diffusion, air layer thickness (m) DIN EN 10626:202 >80
RCPT (Coulombs) ASTM C1202:2019 < 2000
Water Penetration at 5 bar Pressure EN 12390-8:2019 Nil
Water Vapour transmission, (Gm/sq.mtr/day) ASTM D 1653 > 100
Fungi Resistance ASTM G21:2015 Excellent
UV Resistance ASTM D 4584:2011 Excellent
SRI (White Base) ASTM E 1980-19 EN 12898:2019 EN 673:2011 EN 410:2011 98
Shelf Life
Shelf Life

36 months (Storage Temp 2°C - 40°C)

Storage
Storage

Product should be stored in a dry place in their original, properly closed containers at temperature between 2°C - 40°C. Partially emptied container should be closed immediately.

Packing
  • Packing

    Bag:
    1 Ltr, 4 Ltr & 20 Ltr

Application
Handling precautions

Mandatory and recommended industrial hygiene procedures should be followed whenever our products are being handled and processed. For additional information please refer Material safety data sheet.

X